I moved my Scale server into the next room, laundry room, just so it’s out of sight. Replacing the drive is financially out of the question. I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load. Yeah, it’s not helping, thanks. Although it’s empty, so this is probably not the source of the constant HDD noise.
FreeBSD’s sesutil is a tool to interface with the SES devices on your system. You should also configure smartd to monitor your disks and send you alerts, which may give you advanced notice when a drive is starting to fail. These special boards, called SAS Expanders, reduce the total cabling required to provide power and signal pathways to all connected disks.
User reviews about AnyDesk
Obligatory word of warning – mucking with low-level drive settings like this can cause issues. Has anyone found a tool that can use EPC to change the Idle_b and Idle_c values for Exos drives? View an ad to download for free It’s self-hosted and self-managed, so data remains within your company network.Bank-Level EncryptionBanking-standard TLS 1.2 technology protects your computer from unauthorized access. Unparalleled PerformanceOur proprietary video-codec, DeskRT, compresses image data to reduce bandwidth and latency to a level imperceptible to the human eye. With decades of experience in IT management and later as a writer and tutor, she combines technical knowledge with a passion for clear communication.
How to Install AnyDesk on Kali in 3 Steps
I noticed that even when doing nothing, I hear the sound of drives working every few seconds. I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent. I guess it depends on the drives, but don’t think you’ll find any software solution. My Seagate Exos enterprise drives make almost 0 noise actually. The system is never idle really, it’s a server. What causes the constant load on the disk?
- Looking at a few items from the output, we can see the device names (/dev/da0 and /dev/da7 respectively) of the disks in Slot00 and Slot07.
- NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
- Then, click on “Connect” to access the other device.
- When dealing with critical data, you only get one chance to do it right.
- Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong.
However, I noticed that my HDD’s heads park (particulary Seagate Exos) every 3 minutes. ZFS is widely trusted for large-scale storage, but production environments expose design mistakes,… When dealing with critical data, you only get one chance to do it right. The status field is a bitmask supporting a number of different options, but the main ones we care about are 1 (OK), and 2 (FAULTED). When combined with a JSON parser like jq, this can be used to automate tasks for each disk.
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
While I have been aware of this in my home server as well, it is easy to forget to ensure that disks are not silently killing themselves by cycling the heads. With modern, especially Enterprise grade hard drives being able to have hundreds of thousands of head park operations in their service life, is this really an isssue? With the tools presented here, the reader is well armed to react to failed disks and ensure that the wrong disk isn’t accidentally pulled. However, if a disk has died entirely, or a slot is empty, it might not have a device name. Sesutil can also be used to locate the disk in the physical array.While the SES data tells us that there is an 8 TB disk in Slot 06, it does not tell us which slot in the chassis corresponds to 06. Looking at a few items from the output, we can see the device names (/dev/da0 and /dev/da7 respectively) of the disks in Slot00 and Slot07.
We can also see that the disk in Slot07 was recently swapped, and that Slot08 does not contain a disk and its locate LED is activated. SES provides a mechanism to query information from the enclosure, including temperature, fan speed, and status of power supplies. Many backplanes include support for SCSI Enclosure Services (SES).
This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.
Truenas Scale disk activity every few seconds when idle
- The settings you mentioned are already set this way.
- I agree to receive your newsletters and accept the data privacy statement.
- In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives.
- An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives.
- While I have been aware of this in my home server as well, it is easy to forget to ensure that disks are not silently killing themselves by cycling the heads.
- SATA+AHCI improved data transfer speeds, simplicity of communication, and included abilities that we today take for granted, such as “hot swap” and command queueing.
For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.
Program available in other languages
If you need more advanced functionality than mpsutil provides, LSI provides their native tools sas2ircu and sas3ircu for FreeBSD. On my system, this command produces a bright red LED lit for that slot, physically highlighting the correct drive to replace. So, to activate the LED for the first disk displayed above, we first need to determine the enclosure handle number (0001), and then the slot number of the disk (03). This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk. As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.
Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.
When it comes to long-term data storage, there are several strategies and media types that Redditors recommend. It refreshes the disks SMART information every 5 min. ZFS and Btrfs both aim to modernize storage by combining filesystems and volume management, but… Monitoring and maintaining your storage media is one of the most important parts of keeping your data safe.
I set power mode to Idle and advanced power management to the lowest setting (1) which should spin down the disk after 5 mins. Hello,Like many users of Seagate Exos drives, I have found that they park their heads very aggressively, approximately every 2 minutes. AnyDesk allows you to establish remote desktop connections between devices and opens up unprecedented possibilities of collaborating online and administrating your IT network. Its primary purpose is to grant bidirectional remote access between personal computers and mobile devices. To do this, both devices must have the program installed and must allow access through the use of security keys. The current settings for a disk can be queried with the –showEPCSettings flag.
Whether you are a computer technician in charge of technical support or a student who needs to work together with their classmates, AnyDesk is the program you are looking for. Then, click on “Connect” to access the other device. Send it to the other user who has the program and they will be able to access and control your device. It is very popular among professionals who provide technical support. Remember, the key is to act quickly and use the right tools for your specific situation. These practices and tools should give you a solid starting point for recovering your deleted files.
It is fairly well-known among techies that hard drives used in server-like workloads can suffer from poor configuration by default such that they frequently load and unload their heads, which can cause disks to fail much faster than they otherwise would. My Seagate Archive SMR disk (which began life as an external hard drive and was retired from that role when it became too small to hold as much as I wanted to back up to it) apparently doesn’t support reporting EPC settings (since asking for them says so), and initially didn’t accept new values for the idle timers either. The Prometheus Node Exporter is the canonical tool for capturing machine metrics like utilization and hardware information with Prometheus, but it alone does not support probing SMART data from storage drives. While SSDs don’t have any heads reveryplay to park, most do report a media_wearout_indicator that represents the amount of data written to the device in relation to the amount that it’s specified to accept before the Flash storage medium wears out.
Below we will discuss exactly how to do this with FreeBSD’s sesutil or the management tools for your HBA. Though a truism, it bears emphasizing that with a little planning, management and maintenance of storage systems can be made easier and safer. The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.
Direct Attached deployments require a bit more hardware and cabling. The NVMe interface is also extensible to allow operating over the network (where it is known as NVMe Over Fabric or NVMe-oF). NVMe on the other hand, supports multiple queues (often 64 queues, but the official specification allows for up to 65,536 queues) allowing for many commands to be run concurrently. While both SATA and SAS allow multiple commands to be issued at once to the device, these commands cannot actually be executed concurrently—instead, they are queued for sequential operation.